UL Certifications
|
Model |
Ratings |
Standard No. |
File No. |
|
D4A-01 (SPDT, double-break, without indicator) |
A600(Carry current: 10A): 120V AC: Make: 60A, Break: 6.0A 240V AC: Make: 30A, Break: 3.0A 480V AC: Make: 15A, Break: 1.2A 600V AC: Make: 12A, Break: 1.2A Max. VA: Make: 7,200VA, Break: 720VA |
UL508 |
E76675 |
D4A-03 (SPDT, double-break, with neon lamp) |
A300(Carry current: 10A): 120V AC: Make: 60A, Break: 6.0A 240V AC: Make: 30A, Break: 3.0A Max. VA: Make: 7,200VA, Break: 720VA |
D4A-05 (DPDT, double-break, simultaneous operation)
D4A-07 (DPDT, double-break, sequential operation)
D4A-09 (DPDT, double-break, center neutral operation) |
B600(Carry current: 5A): 120V AC: Make: 30A, Break: 3.0A 240V AC: Make: 15A, Break: 1.5A 480V AC: Make: 7.5A, Break: 0.75A 600V AC: Make: 6.0A, Break: 0.60A Max. VA: Make: 3,600VA, Break: 360VA |
Note:
1. Certification is obtained with representative
models. Ask your OMRON representative for details on the standards.
2. The model with a rating of 100,000 operations
is different from the standard model. Specify the desired model when ordering.
3. The applicable standard number is given in the
Standard No. column. The certification report number is given in the File No.
column.
CSA Certification
|
Model |
Ratings |
Standard No. |
File No. |
|
D4A-01 (SPDT, double-break, without indicator) |
A600(Carry current: 10A): 120V AC: Make: 60A, Break: 6.0A 240V AC: Make: 30A, Break: 3.0A 480V AC: Make: 15A, Break: 1.2A 600V AC: Make: 12A, Break: 1.2A Max. VA: Make: 7,200VA, Break: 720VA |
CSA C22.2 No.14 |
LR45746 |
D4A-03 (SPDT, double-break, with neon lamp) |
A300(Carry current: 10A): 120V AC: Make: 60A, Break: 6.0A 240V AC: Make: 30A, Break: 3.0A Max. VA: Make: 7,200VA, Break: 720VA |
D4A-05 (DPDT, double-break, simultaneous operation)
D4A-07 (DPDT, double-break, sequential operation)
D4A-09 (DPDT, double-break, center neutral operation) |
B600(Carry current: 5A): 120V AC: Make: 30A, Break: 3.0A 240V AC: Make: 15A, Break: 1.5A 480V AC: Make: 7.5A, Break: 0.75A 600V AC: Make: 6.0A, Break: 0.60A Max. VA: Make: 3,600VA, Break: 360VA |
Note:
Certification is sometimes obtained with
representative models. Ask your OMRON representative for details on the
standards. The certification report number is given for the applicable standard
number and file number used for certification.
CCC Certification
|
Certified Model |
Certification No. |
|
D4A |
2003010305077615 |
Note:
Certification is obtained with representative models. Ask your OMRON
representative for details on the standards. Some D4A-[]NC models are certifiable,
but there are presently no plans to receive certification.
|