Industrial Automation|

Indonesia

Sitemap

Contact

OMRON IA Global

 
Submit Enquiry
Links

 

D4A-[]N Main Page

 

Information Center

 

Catalogs / Manuals

FAQs

Selection Guide

RoHS Compliant Status

Technical Guide

Replacement Info

 

 

Select Country

 

View Omron product standards certification in your country.

 

   Australia Philippines
   India Singapore
   Indonesia Thailand
   Malaysia
   New Zealand

  

Product Information

Product Index :: Industrial Components :: Switches :: Limit Switches :: General-Purpose

Standards Certification

D4A-[]N General-purpose Limit Switch

 

UL Certifications

 

Model

Ratings

Standard No.

File No.

D4A-01
(SPDT, double-break, without indicator)

A600(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A
240V AC: Make: 30A, Break: 3.0A
480V AC: Make: 15A, Break: 1.2A
600V AC: Make: 12A, Break: 1.2A
Max. VA: Make: 7,200VA, Break: 720VA

UL508

E76675

D4A-03
(SPDT, double-break, with neon lamp)

A300(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A
240V AC: Make: 30A, Break: 3.0A
Max. VA: Make: 7,200VA, Break: 720VA

D4A-05
(DPDT, double-break, simultaneous operation)
D4A-07
(DPDT, double-break, sequential operation)
D4A-09
(DPDT, double-break, center neutral operation)

B600(Carry current: 5A):
120V AC: Make: 30A, Break: 3.0A
240V AC: Make: 15A, Break: 1.5A
480V AC: Make: 7.5A, Break: 0.75A
600V AC: Make: 6.0A, Break: 0.60A
Max. VA: Make: 3,600VA, Break: 360VA

 

Note:

1. Certification is obtained with representative models. Ask your OMRON representative for details on the standards.

2. The model with a rating of 100,000 operations is different from the standard model. Specify the desired model when ordering.

3. The applicable standard number is given in the Standard No. column. The certification report number is given in the File No. column.

 

 

CSA Certification

 

Model

Ratings

Standard No.

File No.

D4A-01
(SPDT, double-break, without indicator)

A600(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A
240V AC: Make: 30A, Break: 3.0A
480V AC: Make: 15A, Break: 1.2A
600V AC: Make: 12A, Break: 1.2A
Max. VA: Make: 7,200VA, Break: 720VA

CSA C22.2
No.14

LR45746

D4A-03
(SPDT, double-break, with neon lamp)

A300(Carry current: 10A):
120V AC: Make: 60A, Break: 6.0A
240V AC: Make: 30A, Break: 3.0A
Max. VA: Make: 7,200VA, Break: 720VA

D4A-05
(DPDT, double-break, simultaneous operation)
D4A-07
(DPDT, double-break, sequential operation)
D4A-09
(DPDT, double-break, center neutral operation)

B600(Carry current: 5A):
120V AC: Make: 30A, Break: 3.0A
240V AC: Make: 15A, Break: 1.5A
480V AC: Make: 7.5A, Break: 0.75A
600V AC: Make: 6.0A, Break: 0.60A
Max. VA: Make: 3,600VA, Break: 360VA

 

Note:

Certification is sometimes obtained with representative models. Ask your OMRON representative for details on the standards. The certification report number is given for the applicable standard number and file number used for certification.

 

 

CCC Certification

 

Certified Model

Certification No.

D4A

2003010305077615

 

Note:

Certification is obtained with representative models. Ask your OMRON representative for details on the standards. Some D4A-[]NC models are certifiable, but there are presently no plans to receive certification.

top